Ann Arbor
Local Reviews
for Ann Arbor, MI
Excellent Service
Kevin - Ann Arbor, MI 48104
Robert was excellent
Steve - Ann Arbor, MI 48103
Robert always does a wonderful job with our fire suppression system inspection. He is always on time and fast working.
Amazing Service!
Jules - Ann Arbor, MI 48104
This service was fast, efficient and completed by extremely kind people! So glad we found this company.
Sprinkler testing
Brad - Ann Arbor, MI 48103
Sean is always very considerate and friendly to the staff and residents. We appreciate him for it!
kitchen suppression system
Brad - Ann Arbor, MI 48103
very through
Excellent Service
Avery - Ann Arbor, MI 48108
My Fire Pros guys; David was professional, on-time, and paid close attention to details. Some times its the small things that make the huge difference.
Nice guys
Sherry - Ann Arbor, MI 48103
Respectful and kind
Another Portion of our Required Inspections
Kevin - Ann Arbor, MI 48108
Staff was on time and friendly. Performed the work without incident and communicated well when they were finished.
New door magnet
Jamie - Ann Arbor, MI 48103
Ron and Dennis were great as usual. Any problems they faced they overcame with professionalism. They did a great job.
Facilities
Glenn - Ann Arbor, MI 48105
Great Service
Super friendly, and efficient!
Sue - Ann Arbor, MI 48104
Super friendly, and efficient!
Sue - Ann Arbor, MI 48104
Super friendly, and efficient!
Sue - Ann Arbor, MI 48104
Great service
Shelly - Ann Arbor, MI 48108
Very thorough and pleasant
Great service
Sandy - Ann Arbor, MI 48105
A Bit Long to Get There, But in the End A Solid System was Installed
Alec - Ann Arbor, MI 48105
Great Service
Nino - Ann Arbor, MI 48103
It was good
Larry - Ann Arbor, MI 48103
Very knowledgeable
GM
Michael - Ann Arbor, MI 48105
Great Service
Barry - Ann Arbor, MI 48104
Jared Jones was very friendly and courteous.
Eduardo A.
James J.
James J.
James J.
John R.
John R.
John R.
Eduardo A.
John R.
Robert G.
Terrence J.
RISER IS IN BASEMENT - Local Bell 3/20/24MV Emailed Kevin regarding inspection date 3/21 Sprinkler Inspection Annual Fire Sprinkler System Inspection (1- Wet) Deficiency: Fire department connection is due for Hydro testing. This is a Stortz connection. Deficiency: Fire department connection check valve is due for internal inspection. 🧐 2- victaulic couplings 4” Deficiency: Fire sprinkler system is due for internal obstruction investigation. 2- 4” victaulic couplings Suggested: Customers insurance company is requesting a hydraulic nameplate for system. Customer will have to contact an engineer to design and do hydraulic calculations on the system. Deficiency: There are two sprinkler heads that have paint on them and must be changed. One is at the top of the skylight on the second floor. The second is at the bottom of the stairwell in the basement. 1- 165° chrome pendant standard response 1- 165° brass upright standard response Deficiency: Sprinkler head box will need sprinkler