Southfield
Local Reviews
for Southfield, MI
System inspection
Griff - Southfield, MI 48033
Mr. James very knowledgeable of the systems he work on also a down to earth person to work with.
Scheduled Maintenance on Server room suppression system
Candido ( Rico ) - Southfield, MI 48075
Very professional and knowledgeable. He answers all my questions.
Excellent Service
Leroy - Southfield, MI 48034
Very professional. Kind and considerate.
Very Pleased
Monica - Southfield, MI 48075
So far, my experience with George and Fire Systems of Michigan has been stellar!
Great Experience
Monica - Southfield, MI 48075
FSM is prompt and responsive. Their employees seem to be exceedingly knowledgeable about their field and working with them is a pleasure.
HSE
Candido - Southfield, MI 48075
Very cordial, knowledgeable and attentive to my questions.
System upgrade
Griff - Southfield, MI 48033
Inspection
Griff - Southfield, MI 48033
Great
Landon - Southfield, MI 48034
Great Services
Landon - Southfield, MI 48034
Great Service
Sal - Southfield, MI 48075
Maintenance Director
Aaron - Southfield, MI 48076
Your Tech did a great job
Awesome Service
Kaye - Southfield, MI 48076
Alex was very polite and professional. He was knowledgeable about the service he provided and gave specifics about what to expect with the next visit.
Great Service
Griff - Southfield, MI 48033
The tech is awesome
Very efficient.
Russ - Southfield, MI 48033
Dave did a very nice job, easy to work with.
Very efficient and personable crew.
Russ Lynch - Southfield, MI 48033
Kitchen Suppression
Griffith - Southfield, MI 48033
The tech very knowledgeable and does great work
Great service
Farouk - Southfield, MI 48075
TJ is always a pleasure too work with
Russ - Southfield, MI 48033
Great Service
Griffith - Southfield, MI 48033
Great
Sean W.
Mark S.
Terrence J.
11/8/23 Confirmed via email with Marc H. / Customer hung up on me DH / Sent email regarding inspection DH Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Domestic System) Deficiency: Local alarm did not activate the panel has multiple troubles on it and must be inspected by a fire alarm technician
Terrence J.
11/8/23 Confirmed with Chris B. Only if we can silence the horns & strobes for 11/14/23 at 10:30amish. DH / Tentative Schedule for 11/14/23 DH Sprinkler Inspection Annual Sprinkler Inspection
Terrence J.
Sprinkler Inspection Annual Fire Sprinkler System Inspection (1 wet system) 5-Year Internal Due: 2024 FDC Hydro Due: 2024 Deficiency: The sprinkler system is due for a gauge change. They must be changed every five years. 2- water 💦 gauges
Terrence J.
11/13/23 Confirmed with Stewart R. for 11/13/23 at 2:30pm DH Sprinkler Inspection Quarterly Fire Sprinkler Inspection (1 Wet System)
Robert G.
Terrence J.
10/31/23 Confirmed by Russ L. for 11/13/23 at 1:30PM DH / Sent email regarding inspection DH Sprinkler Inspection Annual Sprinkler System Inspection (1 Wet, 1 Dry) Deficiency: Dry pendant sprinkler heads are due for testing. We must utilize this time to just change them out. There are only two one in the freezer and one in the cooler. 2- 286° chrome pendant sprinkler heads quick response 1 inch orifice into pipe 12 inches in length This operation for the distance that you have to travel across the top of the coolers should have two men, one up and one down to control any excess water, and to make sure that the heads are put back in place
David H.
David H.
George S.
Alex H.
Terrence J.
10/13/23 Confirmed by Candido for 10/18/23 at 10:30amish DH / Sent email regarding inspection Fire Pump Inspection Monthly Fire Pump Churn Test PO #20440388
Terrence J.
10/17/23 Commercial Fire DH Sprinkler Inspection Annual Sprinkler Inspection ***COMMERCIAL FIRE PAPERWORK REQUIRED***
Terrence J.
10/17/23 Ask Manager to create a Corrigo work order. DH Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System)
Terrence J.
10/6/23 Confirmed by Bob C. for 10/9/23 at 2:30 DH / Sent email regarding inspection DH Sprinkler Inspection Quarterly Sprinkler Inspection
Sean W.
Alex H.
John R.
Terrence J.
The tech will remove and replace the outdated water gauges. NFPA 25 (13.2.7.2) Gauges shall be replaced every 5 years The fire sprinkler piping is due for its 5-year internal obstruction inspection. The purpose of the internal inspection is to view the condition of the piping to identify whether foreign organic and inorganic material is present since the presence of such material can potentially be detrimental to the performance of the sprinkler system. NFPA 25 (14.2.1.1) An assessment of the internal condition of piping shall be conducted at a minimum of every 5 years or in accordance with 14.2.1.2 to inspect for the presence of foreign organic and inorganic material. The fire department connection check valve is due for the 5-year internal inspection. The tech will open the check valve and verify that the valve is clear of debris and sludge so the valve works properly. NFPA 25 (13.4.2.1) Check valves shall be inspected internally every 5 years to verify that all components o