Monroe
Local Reviews
for Monroe, MI
Fire System
Marc - Monroe, MI 48162
David is very knowledgeable took care of our problem and did a Great Job!
extinguisher replacement
Derek - Monroe, MI 48162
KItchen Hood
Derek - Monroe, MI 48162
kitchen hood
Derek - Monroe, MI 48162
Winterization
Derek - Monroe, MI 48162
Winterization
Derek - Monroe, MI 48162
Awesome service
Kattie - Monroe, MI 48162
Always prompted and take pride in the jobs
sprinkler inspection
Derek - Monroe, MI 48162
inspection
Derek - Monroe, MI 48162
Great as always
Cathy - Monroe, MI 48161
We've been using Fire Systems, and our tech, Jim, since I've worked here, and also at my last place of employment. Always friendly, professional, quick, and helpful. Can't think of a single thing I would change. This time, Jim was training another tech. Both were wearing masks and practicing social distancing perfectly.
Great service
Kay - Monroe, MI 48162
He was very knowledgeable, shared all he was doing with us. Very fast and we definitely appreciate that
Awesome service from a experienced tech !!!!!
George - Monroe, MI 48161
Jim is always very polite and answers any questions I may have. Always a pleasure working with Jim.
winter check
Derek - Monroe, MI 48162
winter check
Derek - Monroe, MI 48162
inspection
Derek - Monroe, MI 48162
Alarm retest
Derek - Monroe, MI 48162
ALARM RETEST
Derek - Monroe, MI 48162
annual inspections
Jamie - Monroe, MI 48162
inspections
Derek - Monroe, MI 48162
Tech willing to explain system operation and minor problems that can occur
Fire Pros
Jennifer - Monroe, MI 48162
Alex was quick and efficient. After a little bit of confusion with a different tech, he came out and got it figured out.
Response from Fire Pros | Fire Systems of MI | Adam's Fire :
Thank you for leaving a review, we greatly appreciate your feedback! Alex is an awesome asset and we want to create value for you and your organization, Thanks again and have a fire safe day! Also if you have time, please visit Google and leave us a review there as well, we would greatly appreciate it!
Terrence J.
Special Instructions:Site General Manager is your ONLY POC for scheduling (NOT the Asst GM. or Kitchen Manager or like). The Site GM should also be contacted for any on site service, but if unavailable, obtaining the first name, last name & title of a MANAGER is required noting aGM is unavailable. Sprinkler Inspection **Commercial Fire Paperwork** Annual Fire Sprinkler System Inspection Deficiency: Sprinkler system due for gauge change. 2 gauges Deficiency: Sprinkler system due for five year internal obstruction inspection. 2- 4” Victaulic couplings Deficiency: Check valve FDC are due for five-year internal inspection. 4- 4” Victaulic couplings Deficiency: Fire department connection due for five year Hydro test. 2- 4” Victaulic couplings Deficiency: Sprinkler system check valve/alarm valve due for five-year internal inspection.
Terrence J.
5/8/23 Confirmed with Karen VIA EMIL FOR 5/10/23 AT 8:00AM DH / Please enter through the Shelter entrance from the East Parking lot Annual Sprinkler Inspection 1 Dry System 1 Wet System
Jim S.
3/22 Scheduled with manager Alyssa. Eric will MOD KM TECHNICIAN - Please have manager open a Corrigo work order if there are any deficiencies so a quote can be submitted. Thanks!!!! Kitchen Suppression, Portable Extinguishers, and Emergency / Exit Lights Inspection Semi-annual Kitchen System Inspection Annual Extinguisher Inspection Annual Emergency/Exit Light Inspection Deficiency: Number of Extinguishers Left at Job: 3 Deficiency: Three 5# abc fire extinguishers due for 6yr. maintenance. Deficiency: Emergency light in kitchen and middle dining room needs new batteries.
Tyler H.
Needs new mag lock. Ademco keypad and outdoor relay keypad switch power to the lock This quote is for a new maglock to be installed on the entry door of the memory care . This maglock will be controlled by the keypads which have constant power and drop power when code is entered. The maglock will also drop power when fire alarm is activated. This includes installation, parts, programming, testing with the fire alarm , permits, and inspection. We will remove the power from the von duprin crash bar and reuse it for the maglock. We will reuse the keypads that tie into the crash bar and confirm they drop power when activated . Technician must have lock tight and universal screws and bolts if needed. Make sure work area is cleaned up of any debris. Wire and test to confirm proper adjustments have been made . Demo to customer before leaving site.
Ron R.
Jim S.
2/24 rescheduled with Munim. Extra time given for first time service. km 2/22 Scheduled with customer via emails. km Kitchen Suppression and Portable Extinguishers Inspection Semi-Annual Kitchen Suppression System Inspection Annual Fire Extinguisher Inspection (7) Deficiency: Electric fuel source on center pressure fryer does not de energize upon fire system actuation. Deficiency: Broiler drawer under grill is un-protected. Deficiency: Number of Systems failed : 1 Inoperable Deficiency: 5# abc fire extinguisher by produce room has a broken handle. Deficiency: 5# abc fire extinguisher by customer restrooms due for 6yr. maintenance. Deficiency: Number of Extinguishers Left at Job: 2 Deficiency: K-Class fire extinguisher out of hydro date.
Mark S.
Terrence J.
2/22/23 Sent email regarding inspection DH Sprinkler Inspection Annual Fire Sprinkler System Inspection Deficiency: Sprinkler system is due for gauge change Deficiency: There is no evidence of five-year internal obstruction investigation of this sprinkler system. Deficiency: There is no evidence of five-year internal check fire 🔥 department connection check valve Deficiency: The egg cooler has one drive pendant that is out of date it is 12 inches long Deficiency: Meat cutting room has dry pendant heads out of date This includes the other external walk-in coolers and freezers Deficiency: Inspectors test valve will need sign Deficiency: Fire department connection will need caps
Sean W.
Tyler H.
This quote is for 2 technicians to come out and run wire for a gate maglock. Conduit and boxes between build and gate. Install direct burial cable between mechanical room and the gate. Run FPLP cable between the fire alarm panel to the mechanical room . Interconnect fire alarm relay with the maglock on a double pole relay at the FACP. Mount 2 exterior corby's at the gate . Either Keypad will drop power to the maglock, Fire Alarm will drop the power to the mag lock. Program and test.
Sean W.
Sean W.
Jim S.
Jim S.
Techs - If there are any deficiencies, please have manager open a Corrigo work order so a quote can be submitted. Portable Extinguishers, Emergency / Exit Lights, and Kitchen Suppression Inspection Annual Extinguisher Inspection Annual Emergency/Exit Light Inspection Semi-annual Kitchen System Inspection Deficiency: Number of Systems failed : 1 Suggested: 2- clogged nozzles need to be replaced. NL-UB needed for salamander. NL-D2 needed for grill.