2/9/23 Sent email regarding inspection DH Sprinkler Inspection Quarterly Fire Sprinkler Inspection (1 Wet System)
Sean W.
David H.
Sean W.
Mark S.
Mark S.
Terrence J.
Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System) 5-Year Internal Due: FDC Hydro Due: Deficiency: Out dated dry heads are due for testing. Heads are currently over 48”, replace with standard dry heads and pipe. 6 total installed Kitchen cooler: (3) 12” chrome dry pendants (3) 1” tees (3) 1” plugs Kitchen freezer: (1) 18” chrome dry pendant (1) 1” tee (1) 1” plug Kitchen beer cooler: (2) 12” chrome dry pendants (2) 1” tees (2) 1” plugs (1) can of spray foam 42’ 1” pipe Deficiency: Corroded heads in kitchen. (10) 1/2” 155 QR chrome pendants with chrome semi recessed escutcheons Also outdated quick response sprinkler heads must be tested Deficiency: Recalled heads in spare head box, replace. (2) 1/2” 155 QR chrome pendants (1) 1/2” 155 QR chrome sidewall Note: heads installed through out system are not recalled Deficiency: front kitchen area has four painted heads. missing four globe chrome esecu. mod. j-jn. front lobby has one head too be raised.
Mark S.
George S.
Terrence J.
11/15/22 Confirmed with Stewart W. for 11/15/22 for 11:30amish. DH Sprinkler Inspection Quarterly Fire Sprinkler Inspection (1 Wet System)
Sean W.
Alex H.
Terrence J.
Sprinkler and Fire Hydrant Inspection 8/1/22 Email sent regarding inspection DH Annual Sprinkler Inspection (3 Wet, 2 Dry, and 2 PIV Sprinkler Systems) Annual Hydrant Inspection (2 Fire Hydrants) Deficiency: Systems due for 5 year internal inspections. Last 5 year the Viking dry piping was checked and the 8” riser #3 was checked. This inspection the 4” wet and the Tyco dry piping will be inspected. Include 4 new 4” victaulic couplings and 2 new 2.5” victaulic couplings when quoting. Lift required to reach piping. Deficiency: All check valves are due for 5 year internal inspections. Viking dry valve for loading dock east, Tyco dry valve for loading dock west. 4” alarm check on riser #2 8” alarm check on riser #1 and riser #3. FDC check valve needs 4” flange gaskets Deficiency: Inspectors test valve for riser #3 is not access able. Valve needs to be lowered so it can be reached for testing. ITV located in north east corner of building. New 1” ball valve 10’ black 1” pipe 1- 90 degree 1”
Alex H.
Terrence J.
8/9/22 Confirmed with Rick P. for 8/12/22 at 8:00am / Sent email regarding inspection. DH Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System)
Alex R.
Corrected Deficiencies from recent inspection
Alex R.
Completed annual Fire Extinguisher inspection for 2022