Livonia
Local Reviews
for Livonia, MI
Vice President
Tim - Livonia, MI 48150
great service
Gordon - Livonia, MI 48150
TJ very nice to work with.
Vice President
Tim - Livonia, MI 48150
Great service!
Sam - Livonia, MI 48154
Mark was great. Very knowledgeable and helpful. Highly recommend.
great service
Rory - Livonia, MI 48150
tj was very polite.
Excellent service, flexible working hours. They were able to complete inspection, service and repair. Without any disruption in our shop or office are
Bill - Livonia, MI 48150
All of the gentlemen that I dealt with during the quote for service, the inspection process and the technicians that performed the service and repairs, were very professional. I look forward to using their services for our yearly inspections.
Excellent service thus far. This is only the inspection phase. Service phase is next, after quote is submitted.
Bill - Livonia, MI 48150
My walk through our fire system with TJ (service technician) was very thorough. He pointed out items that need to be addressed. TJ did this inspection in very professional manor.
Excellent serive
Wilbert - Livonia, MI 48150
Jim gave a great overview of fire extinguisher re-certification frequency including hydro testing etc
Excellent Service
John - Livonia, MI 48152
Great service, friendly
Connie - Livonia, MI 48154
Excellent Service
Sam - Livonia, MI 48154
Great service once again by Mark. Highly recommend.
great service
Rory - Livonia, MI 48150
Excellent Job
Xu - Livonia, MI 48154
Excellent Service
Sam - Livonia, MI 48154
Great help
James - Livonia, MI 48154
Great Service!
wwjd216 - Livonia, MI 48150
Jared with Fire Pros has always done a great job for us. 100% recommend
Appreciated the tech's initiative
Sallie - Livonia, MI 48152
I was late getting into the building, but the tech was able to enter with another group and knew where everything was and conducted the inspection before I arrived. We appreciate his timely work and and letting me know there were no issues.
Fire Systems Inspection
Brooke - Livonia, MI 48150
Very thorough and done quickly. Explained what he was doing and kept it clean.
Great Service
Stephen - Livonia, MI 48150
Great service
Duane - Livonia, MI 48152
Tech was very prompt and professional, great company all the way around, no complaints
Robert G.
Eduardo A.
Terrence J.
4/9/24 Confirmed with Kristy for 4/12/24Sent email regarding inspection DH 2/29/24MV Kristy is calling me back 2/21/24MV Emailed Kristy regarding inspection date 2/22, left a voicemail for Josh Sprinkler and Stand Pipe Inspection Annual Sprinkler System Inspection Annual Standpipe Inspection (1) Deficiency: Sprinkler system is due for five-year internal obstruction investigation piping. 1- 4” victaulic coupling Deficiency: Fire department connection check valve is due for internal inspection. 2- victaulic couplings Deficiency: Fire department connection due for Hydro test
Mark S.
Robert G.
James J.
Sean W.
Sean W.
George S.
Robert G.
Sean W.
Robert G.
Mark S.
Mark S.
Terrence J.
2/28/24 Confirmed by Rick 248-802-9665 Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System) Inoperable Deficiency: Sprinkler system flow switch must be replaced. It is frozen and will not move at all. 1- 3” waterflow switch Deficiency: Sprinkler system is due for gauge change. 1- sprinkler gauge Deficiency: Sprinkler system is due for five year internal obstruction investigation. 2- 3” victaulic couplings Deficiency: There is no evidence of five-year internal inspection, fire department connection, check valve. 2- 4” victaulic couplings Deficiency: There is no evidence of five-year Hydro test, fire department connection Deficiency: Fire department connection will need signage located above it to identify where it is. 1- FDC sign Deficiency: Sprinkler spare head box will need a universal wrench. 1- universal sprinkler head wrench
Terrence J.
2/6/24 Confirmed with Andrea for 3/4/24 at 10:00amish DH Annual Sprinkler Inspection (1 Wet Sprinkler System) Sprinkler Inspection Deficiency: Sprinkler system is due for gauge change. 1- sprinkler gauge Deficiency: Sprinkler system is due for five year internal obstruction investigation. 2- victaulic coupling Deficiency: Sprinkler system is due for five-year tunnel, check valve inspection, fire department connection. 2- 4” victaulic couplings Deficiency: Sprinkler system is due for Hydro test fire department connection. 1- 4” victaulic coupling
Robert G.
Jim S.
2/26 Scheduled with Angie. She'll be on site for you km 1/17/24 left VM SM Annual Extinguisher Inspection (4)ABC's (1)K Semi-annual Kitchen System Inspection Ansul R102-S3 (3)500 links (1)360 link (10)Nozzles Deficiency: Number of Extinguishers Left at Job: 2 Portable Extinguishers and Kitchen Suppression Inspection