Dearborn
Local Reviews
for Dearborn, MI
Great Service
Helen - Dearborn, MI 48126
The Tech did a great job, communicated throughout the process. Very nice and friendly guy.
Friendly and professional know what they were doing.
Khal - Dearborn, MI 48126
Satisfied
Great Service
Faiz - Dearborn, MI 48124
Professional and knowledgeable
Area Coach
Austin - Dearborn, MI 48126
Fantastic job! Great guys!
Great Service
Josh - Dearborn, MI 48124
great service - he was early but it accomodated both of us
Janet - Dearborn, MI 48126
great company!
Always great service.
RJ - Dearborn, MI 48126
We have used alex with fir pros many times for commercial jobs and they always do amazing work. Due to conditions beyond their control, they were not able to help us on the most recent job we had requested, but Alex explained very well what has to happen and how we should go about correcting some things. 5 stars for sure, and we always recommend them.
Great Service
Mohamad - Dearborn, MI 48124
Great Customer Service!!!!!!
Roger - Dearborn, MI 48126
Jared was great. Called as I requested. He explained everything as he went to each floor. He also went over the whole inspection when he was finished. Made sure the contact information was correct. A great job out of the way.
Great Service
marc - Dearborn, MI 48128
Amazing
Mustapha - Dearborn, MI 48120
Awesome crew, did the job well and in a timely matter.
Response from Fire Pros | Fire Systems of MI | Adam's Fire :
Thank you for leaving your review! We greatly appreciate your feedback and are glad that we provided you valuable service! At your convenience, please consider sharing your experience on Google as well. https://tinyurl.com/yylegs7q Thanks again and have a fire safe day!
Outstanding Service
Bill - Dearborn, MI 48126
Sean W.
Mark S.
Michael G.
Robert G.
Jim S.
9/6/23 confirmed with Imad SM Kitchen Suppression Inspection SEMI ANNUAL KITCHEN SYSTEM INSPECTION (1) Ansul 6 Gallon
Terrence J.
8/21/23 Sent email regarding Inspection DH OS&Y's are chained and locked. Sprinkler Inspection Annual Fire Sprinkler System Inspection Deficiency: Sprinkler system needs gauge change Deficiency: Sprinkler system will need a sprinkler head box 6 chrome pendant sprinkler heads 165° and a universal wrench there are none on site Deficiency: Fire sprinkler system will need one inspectors to sign and to control valve signs
Terrence J.
8/15/23 Confirmed with Kelly for 8/24/23 at 10:00am / Sent email regarding inspection DH 7/27/23 Lisa not in the office will call back when she returns / Sent email regarding inspection DH Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System) Deficiency: Pressure gauge is outdated. Deficiency: 5 year internal pipe obstruction investigation is due. Deficiency: 5 year FDC check valve inspection/hydrostatic test is due. Deficiency: 5 year FDC check valve inspection/hydrostatic test is due. 2- 4” Victaulic couplings Deficiency: 5 year FDC check valve inspection/hydrostatic test is due. Deficiency: 5 year internal pipe obstruction investigation is due. 2- 4” Victaulic couplings Deficiency: Pressure gauge is outdated. 1- sprinkler gauge
Terrence J.
8/15/23 Sent email regarding inspection DH 8/8/23MV Emailed Fadi regarding inspection date 8/9, Fadi confirmed for after 10 am Stand Pipe and Sprinkler Inspection Quarterly Standpipe Inspection (1) Quarterly Fire Sprinkler System Inspection (1 wet)
Terrence J.
8/4/23 Sent email regarding inspection DH Sprinkler Inspection Annual Sprinkler Inspection Deficiency: There is no evidence of five-year Hydro test on fire department connection Deficiency: There is no evidence of five-year internal inspection fire department connection check valve. 2- Victaulic couplings Deficiency: The wet and dry sprinkler system will need gauge change. 3- sprinkler gauges Deficiency: There is no evidence of internal inspection of a dry sprinkler valve with strainers and all. 1 lot Gasket material Deficiency: There is no evidence of five-year internal obstruction investigation on sprinkler system. 2- Victaulic couplings 4”
Terrence J.
8/16/23 10:54am (EA) Josh called and confirmed the scheduled date 8/21/23 in the am Sprinkler Repair The fire sprinkler system control valve is not monitored. The tech will add supervision of the valve. This will prevent tampering with. NFPA 25 (13.3.1.3) Each normally open valve shall be secured utilizing a seal or a lock or shall be electrically supervised in accordance with applicable NFPA standards. No spare headbox is installed at this location with the spare sprinkler heads and head wrench. The tech will install (1) Spare Headbox, (6) spare sprinkler heads, and (1) Head wrench. NFPA 25 (5.4.1.5.4) The stock of spare sprinklers shall include all types and ratings installed and shall be as follows; Facilities having under 300 sprinklers – minimum of 6 spare sprinklers NFPA 25 (5.4.1.5.2) The sprinklers shall be kept in a cabinet located where the temperature in which they are subjected will at no time exceed 100 degrees F (38 degree C) NFPA 25 (5.4.1.5.5) One sprinkler wren
Robert G.
Terrence J.
7/28/23 Sent email regarding inspection DH 6/16/23MV Emailed Rex regarding inspection date 6/27, waiting on confirmation Sprinkler Inspection Annual Fire Sprinkler System Inspection (1 wet system) Deficiency: Sprinkler system due for gauge change 1 300# wet sprinkler gauge Deficiency: There is no evidence of five year fire department connection hydrotest. 2-4” Victaulic couplings Deficiency: Sprinkler system will need signs and chain on all the valves to OSNY valves one inspectors test one main drain Deficiency: There is no evidence of five-year sprinkler system fire department connection hydrotest. Deficiency: Sprinkler systems are due for signs on all valves 1 inspectors test one main drain 2 Os&y. Deficiency: Sprinkler head box needs one universal wrench Deficiency: Sprinkler valves in the chain and locks. 2- locks 🔐 2- ‘ lengths of chain. Deficiency: Flow switch does not trip any alarm 🚨 Alarm tech will have to check this out
Mark S.
Terrence J.
7/27/23 Confirmed with Helen W. for 7/31/23 around 10:00amish DH / Sent email regarding inspection DH We need to be complete before 12:00 Helen needs to leave. 7/11/23 See if you have time to do these as well. DH Sprinkler Inspection Quarterly Fire Sprinkler System Inspection (2 wet, 1 dry systems)
Mark S.
Robert G.
Robert G.
Terrence J.
6/20/23 Confirmed with Tony D. for 6/23/23 at 10:00 am DH / Sent email regarding inspection DH Sprinkler Inspection Annual Sprinkler Inspection (1) Wet Deficiency: There is no evidence of five-year Hydro test fire department connection. 2- 4” Victaulic couplings Deficiency: There is no evidence of five-year internal check valve inspection and fire department connection. 2- 4” Victaulic couplings Deficiency: There is no evidence of five-year internal obstruction investigation sprinkler system. 2- 4” Victaulic couplings
Terrence J.
6/15/23 Sent email regarding inspections DH Sprinkler Inspection Annual Fire Sprinkler Inspection