Terrence J.
Notice of Non Compliance and Repair Proposal Fire Systems of Michigan recently inspected/serviced the fire sprinkler system at your establishment in accordance with NFPA guidelines. While inspecting/servicing your fire sprinkler system, it was determined to be "Non-Compliant". The attached proposal summarizes the non-compliance issues that were found during the inspection/service and the costs and actions needed to correct them. Fire Systems of Michigan strongly recommends that your sprinkler system is repaired so that it will become compliant. The fire sprinkler system as-is will not work properly due to the referenced deficiencies and may not extinguish, suppress or control a fire. This is a safety hazard and may contribute to damage or injury to your property and individuals in the event of a fire. Please contact me as soon as possible to review the attached proposal and schedule the repair to your fire suppression system. I look forward to working with you to bring your sprinkler s
Mark S.
George S.
Robert G.
George S.
George S.
Terrence J.
11/1/23 Confirmed for 11/3/23 DH Sprinkler Inspection Deficiency: Hydraulic nameplate is not legible, and must be made to be legible by customer Annual Fire Sprinkler Inspection (1 Wet System) 5-Year Internal Due: FDC Hydro Due:
Terrence J.
Sprinkler Repair COMMERCIAL FIRE PAPERWORK ATTACHED: The tech will remove and replace the outdated water gauges. NFPA 25 (13.2.7.2) Gauges shall be replaced every 5 years
George S.
George S.
George S.
Robert G.
Jim S.
Kitchen Suppression and Portable Extinguishers Inspection Semi-Annual Kitchen Hood Fire Suppression System Inspection (PCL-460) Annual Fire Extinguisher Inspection (3 FE?) Deficiency for Pyro Chem KK-II PCL-460 Left of Hood: Electric 110v outlet under hood near grill does not de energize upon fire system actuation. Deficiency for Pyro Chem KK-II PCL-460 Left of Hood: Exhaust fan on left hood not working prior to test. Deficiency: Number of Systems failed : 1