Auburn Hills
Local Reviews
for Auburn Hills, MI
Good service
LA - Auburn Hills, MI 48326
TJ was great to work with and answered all questions. Arrived on time and made sure we were satisfied with the job before he left.
Great service
Mark - Auburn Hills, MI 48326
Technician was on time, knowledgeable and performed the work as outlined.
Great work, awesome attention to detail
Mark - Auburn Hills, MI 48326
Work was conduction quickly and accurately. I appreciated their feedback.
Job well done
Deric - Auburn Hills, MI 48326
Poor service , unprofessional
Meagan - Auburn Hills, MI 48326
Very very unprofessional. Came in when we opened and threw his stuff on our counter , he stepped on our grill with his shoes and it was gross. Asked for a free sub at the end .
Great Job
Deric - Auburn Hills, MI 48326
Great Fast accurate Service
Good Job
Deric - Auburn Hills, MI 48326
Good Job
Deric - Auburn Hills, MI 48326
Excellent Service and Care
Luke - Auburn Hills, MI 48326
I have been with my company for over a year now, and have had a lot of companies do service and different things to our building/machines. We believe in a correct way, an aesthetic way, and a safe way. We appreciate when Fire Systems of Michigan comes because they handle our building like its their own. Jered is an outstanding professional service tech. Thank you
Annual Inspection
Gil - Auburn Hills, MI 48326
Gerald did job today doing the inspection.
Great working with Fire Pros!
Dave - Auburn Hills, MI 48326
We have always had good service from Fire Pros. Your representatives are knowledgeable, friendly and thorough. Thanks
Great Service
Caitlyn - Auburn Hills, MI 48326
Matt was extremely professional and handled the inspection in a timely fashion.
food line leader
Tim - Auburn Hills, MI 48326
very informative.
Terrence J.
Must have safety glasses and high vis vest in shop. Also will need key for lock on WPIVs Will also need 2nd floor janitors closet unlocked to access ITV Sprinkler Repair Wall PIV tamper failed to operate and open closed indicator needs to be adjusted. The tech will troubleshoot the switch. Inoperable Deficiency: The tamper switch that I was sent out to adjust has a wiring problem that must be addressed by the fire alarm division the tamper switch manually trips, but does nothing in the system. All the wiring is on the open and close, but there are no wires on the common. I’m not sure if this is correct or not. 1- fire alarm technician to correct problem
Terrence J.
Sean W.
James J.
James J.
George S.
James J.
George S.
Robert G.
Robert G.
John R.
George S.
Terrence J.
11/6/23 Material in shop in Novi if needed. DH 10/30/23 Confirmed by Keith Tillman for 11/8/23 at 8:00am DH / Sent email regarding inspection DH Hydrostatic Testing, Sprinkler, and Obstruction Investigation Repair The FDC is due for its 5-year hydro-static testing. The tech will perform this test on the Fire Department Connection (FDC). NFPA 25 (13.8.5) The piping from the fire department connection to the fire department connection check valve shall be hydro-statically tested at 150psi (10 bar) for 2 hours at least once every 5 years. The tech will remove and replace the outdated water gauges. NFPA 25 (13.2.7.2) Gauges shall be replaced every 5 years The systems check valve is due for its 5-year internal inspection. The tech will open the valves and verify there is no debris or damage that can prevent the valve from operating as designed. NFPA 25 (13.4.1.2) Alarm valves and their associated strainers, filters, and restrictions orifices shall be inspected internally every 5 yea
George S.
George S.
George S.
Robert G.
George S.
Jim S.
8/2/23 confirmed with Michael SM Portable Extinguishers Inspection Annual Fire Extinguisher Inspection (22 FE) Deficiency: Number of Extinguishers Left at Job: 7 Deficiency for 10 lb ABC Sanctuary staircase landing: Five 10# abc fire extinguishers due for 6 yr. maintenance. 4 Badger and 1 Kidde. One 10# abc and one 5# abc fire extinguishers (Ansul) leaked down after 6 yr. maintenance was done last year.
Terrence J.
Notice of Non-Compliance and Repair Proposal Adams Fire Protection Co. recently inspected/serviced the fire sprinkler system at your establishment in accordance with NFPA Standard for Inspections, Testing, and Maintenance Requirements (2017 Edition). While inspecting/servicing your fire sprinkler system, it was determined to be "Non-Compliant". NFPA 25 (4.1.5.1) The property owner or designated representative shall correct or repair deficiencies or impairments. The attached proposal summarizes the deficiency/impairment issues that were found during the inspection/service and the costs and actions needed to correct them. Adams Fire Protection Co. strongly recommends that your sprinkler system is repaired so that it will become compliant. The fire sprinkler system as-is may not work properly due to the referenced deficiencies/impairments and may not extinguish, suppress or control a fire. This is a safety hazard and may contribute to damage or injury to your property and individuals in t