Westland
Local Reviews
for Westland, MI
Awesome job
Travis - Westland, MI 48185
Fire extinguisher service
Eric - Westland, MI 48185
Jarrod from Fire Systems of Michigan serviced our fire extinguishers at our facility and I cannot be more satisfied. He was very kind and knowledgeable. He spent time to show me what to look for to keep our animals and staff safe in the case of a fire.
Great service, very helpful!
Travis - Westland, MI 48185
Great Service
Keith - Westland, MI 48185
Prompt and professional.
Great Service!
Travis - Westland, MI 48185
Excellent Service!
Susan - Westland, MI 48186
We had our annual fire extinguisher inspection today. It is always a pleasure to have this completed by Jared. He is extremely knowledgeable and efficient.
Great Service
Kara - Westland, MI 48185
Arrived on time! Was very thorough on coaching staff on how to use the alarm system in every possible scenario!
A+++
Bobby - Westland, MI 48185
Great service thank you
Michael - Westland, MI 48186
He was a great technician he checked everything on all our fire extinguishers very detailed on all his work while being a true professional thank you very much please send him back next year
General Manager
Phillip - Westland, MI 48185
Good service
Terrence J.
Sprinkler Repair COMMERCIAL FIRE PAPERWORK: The fire sprinkler system control valve is not monitored. The tech will add supervision of the valve. This will prevent tampering with. NFPA 25 (13.3.1.3) Each normally open valve shall be secured utilizing a seal or a lock or shall be electrically supervised in accordance with applicable NFPA standards. Deficiency: Missing supervision for control valve Small lock and change
Terrence J.
4/3/24 Customer cancelled inspection for 4/5/24 per Kathy M. DH 2/28/24 Sent email regarding inspection DH and also regarding backflow DH Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System)
John S.
Sean W.
James J.
Sean W.
Terrence J.
Sprinkler Service Call Derek called in a service call for leaking heads please call when in route 330-671-1520
Terrence J.
2/27/24 Confirmed with Niko for 2/28/24 in the afternoon. DH / Sent email regarding inspection DH Sprinkler Inspection Annual Sprinkler Inspection Deficiency: Sprinkler system number one is due for internal obstruction investigation of piping. 2- victaulic couplings Deficiency: Sprinkler system number one is due for internal inspection of check valve. Fire department connection. 2- victaulic couplings Deficiency: Sprinkler system number one is due for Hydro test fire department connection. 1- victaulic coupling Deficiency: Dry pendant, heads in cooler are due to be replaced. 4–286° chrome pendant adjustable, sprinkler heads quick response these are dry pendant heads Deficiency: Sprinkler system number two is due for five-year internal obstruction investigation of piping. 2- 4” victaulic couplings
James J.
Terrence J.
2/8/24 Sent email regarding inspection DH 12/29/23MV Emailed Henry regarding inspection date 1/4, waiting on confirmation 12/13/23MV Henry confirmed Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System) Deficiency: There is no evidence of five-year internal obstruction investigation piping Red gasket material Deficiency: Sprinkler head box will need universal wrench 1- universal head wrench Deficiency: Fire department connection will need new stortz cap. 🧢 1- 4” stortz connection cap Deficiency: Sprinkler system is due for gauge change. 2- sprinkler gauges. Deficiency: There is no evidence of five-year fire department connection Hydro test. Red gasket material Deficiency: Alarm check valve has no evidence of five-year internal inspection. Red gasket material Deficiency: Fire department connection, check valve has no evidence of five-year internal inspection. Red gasket material Deficiency: Control valves, as well as inspectors test valve will need signs
Terrence J.
Terrence J.
1/26/24 Sent email regarding inspection DH Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System) 5yr Internal Due: 2026 FDC Hydro Due: 2026
Mark S.
Matt P.
Terrence J.
1/5/24 Mater in Shop in Novi / DH Sent email regarding inspection DH Sprinkler Repair The tech is to install the FDC ring indicator per Edward Snorf's request. For the ring to be installed the connection will be removed and then replaced.
Terrence J.
\ Sprinkler Repair A tech responded to a service call because the outside bell was going off even though the main panel was showing normal. The tech noted that the low air switch will need to be replaced. Deficiency: Potter ps 40 low air switch
Terrence J.
TECHNICIANS - when your techs are doing lighting checks, if any of the connectors are not attached to the battery terminals, could you please have them attach them. My techs have found a few disconnected, and can’t assess battery until we know if it will charge. Regards, Greg Fuchs, CRFP Sr. Facilities Manager – Applebee’s/Wendy’s/MOD Pizza/Olga’s Kitchen TEAM Schostak Family Restaurants Cell (734) 751-4571 TECHNICIAN - Please have manager open a Corrigo work order if there are any deficiencies so a quote can be submitted. Thanks!!!! Please let Greg Fuchs (734) 751-4571 - know what areas are covered by sprinklers. BOH storage? Sprinkler Inspection Annual sprinkler Inspection Deficiency: Domestic sprinkler system, backflow preventer valve will need two control valve signs. It will also need one control valve sign on the drain and it will also need chain and 🔐 to secure handles on valve. Deficiency: Sprinkler head box needs sprinkler heads for standard response 165° grass pendant It wi
Matt P.
Robert G.
Terrence J.
Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet System) 5-year Internal Due: 2024 FDC Hydro Due: 2024