Southfield
Local Reviews
for Southfield, MI
on time and very communicative
ED - Southfield, MI 48034
JJ was prompt, courteous and thorough. I will be rating him 5 stars.
Excellent Service.
Andre - Southfield, MI 48034
I would like to thank Jim for being patient and courteous with us throughout the inspection.
Great Service
Landon - Southfield, MI 48034
Excellence
Tanya - Southfield, MI 48033
Great Service
Fire System Repair
Griff - Southfield, MI 48033
He’s very knowledgeable and downright the best.
He was great
Bob - Southfield, MI 48076
Tech was vary good at what he does.
System inspection
Griff - Southfield, MI 48033
Mr. James very knowledgeable of the systems he work on also a down to earth person to work with.
Scheduled Maintenance on Server room suppression system
Candido ( Rico ) - Southfield, MI 48075
Very professional and knowledgeable. He answers all my questions.
Excellent Service
Leroy - Southfield, MI 48034
Very professional. Kind and considerate.
Very Pleased
Monica - Southfield, MI 48075
So far, my experience with George and Fire Systems of Michigan has been stellar!
Great Experience
Monica - Southfield, MI 48075
FSM is prompt and responsive. Their employees seem to be exceedingly knowledgeable about their field and working with them is a pleasure.
HSE
Candido - Southfield, MI 48075
Very cordial, knowledgeable and attentive to my questions.
System upgrade
Griff - Southfield, MI 48033
Inspection
Griff - Southfield, MI 48033
Great
Landon - Southfield, MI 48034
Great Services
Landon - Southfield, MI 48034
Great Service
Sal - Southfield, MI 48075
Maintenance Director
Aaron - Southfield, MI 48076
Your Tech did a great job
Awesome Service
Kaye - Southfield, MI 48076
Alex was very polite and professional. He was knowledgeable about the service he provided and gave specifics about what to expect with the next visit.
Great Service
Griff - Southfield, MI 48033
The tech is awesome
James J.
Mark S.
Terrence J.
3/7/24 Confirmed by Veronica DH / Sent email regarding inspection DH Annual Sprinkler System Inspection (2) systems Sprinkler Inspection
Jim S.
2/28/24 Scheduled with Larry. Tech arrival at 5:00 AM PROMPT. They will meet you on site. All 3 systems are in the same kitchen on the 4th floor. Larry is working with Alarm Company to get alarms in test, but would like you to see if the panel can be put into "walk test" so we don't have to light up the entire building from now on. km Kitchen Suppression and Portable Extinguishers Inspection Inspect Three Ansul 3 gl systems Annual Fire Extinguisher Inspection in kitchen only Deficiency: Number of Extinguishers Left at Job: 2
Terrence J.
Sprinkler Service Call Bob Clark 248-670-8429 needs the sprinkler head & escutcheon replaced in the kitchen by the dishwasher. He also needs 2 escutcheons for the heads in the walk in freezer plus he wants (4) extra escutcheons.
Terrence J.
2/26/24 Confirmed with Candido for 2/27/24 at 8:00am DH Fire Pump Inspection Monthly Fire Pump Churn Test PO #20440388
James J.
Matt P.
Sean W.
Robert G.
James J.
Terrence J.
1/17/23(TJV)- spoke with Mark on pricing Mark to get with customer to confirm charge 1/5/24 Confirmed with Mark with Mark from Eagle for 1/31/24 DH Sprinkler Inspection Annual Sprinkler Inspection Deficiency: Sprinkler system is due for gauge change 1- sprinkler gauge Deficiency: Control valves and inspectors test valves will need signs 6-control valve signs 6- inspectors test valve signs Deficiency: Sprinkler system is due for internal obstruction investigation of piping. This will have to be done in stairwells. 4-2.5” victaulic couplings Deficiency: Sprinkler system is due for internal inspection fire department, connection check valve Red rubber gasket material Deficiency: Sprinkler system is due for five-year Hydro test of fire department. Connection access is a little suspect will have to be investigated to make sure it can be done. Red rubber gasket material Deficiency: Sprinkler system is due for gauge change 1- sprinkler gauge Deficiency: Sprinkler system is due for in
Robert G.
Terrence J.
1/17/24 Confirmed with Candido for 1/22/24 at 1:00pm DH Fire Pump Inspection Monthly Fire Pump Churn Test PO #20440388
Terrence J.
1/4/24 Confirmed with Griff W. for 1/11/24 at 11/:15am DH / Sent email regarding service DH Sprinkler Repair The tech will remove and replace the outdated water gauges. NFPA 25 (13.2.7.2) Gauges shall be replaced every 5 years
Terrence J.
Sprinkler Inspection Annual Sprinkler Inspection ***COMMERCIAL FIRE PAPERWORK/WO REQUIRED***
Terrence J.
1/4/24 Sent email regarding inspections DH Sprinkler Inspection Quarterly Sprinkler Inspection
Sean W.
Sean W.
Terrence J.
12/22/23 Confirmed with Landon for 12/26/23 at 2:00pmish DH / Sent email regarding inspection DH 12/12/23MV Emailed Landon regarding inspection date 12/13, waiting on confirmation Sprinkler Inspection Annual Sprinkler System Inspection (2 wet systems - Piping is CPVC)