Saginaw
Local Reviews
for Saginaw, MI
Very friendly, Great service
Chris - Saginaw, MI
The guys were very friendly, Helpful in learning more about how to solve our problem we had! Would highly recommend them to other companies!
Emergency Service
Melissa - Saginaw, MI
Professional and Thorough
Melissa - Saginaw, MI
Self Sufficient and Thorough
Melissa - Saginaw, MI
Awsome & Quick
Melissa - Saginaw, MI
Alex is always thorough and concise! Vary happy with his service!
Great service
Lorie - Saginaw, MI
Alex is always available to assist whenever i have an issue
Great Tech Service
Lorie - Saginaw, MI
Alex is always available to assist whenever a issue arises
I prefer working with Alex
Melissa - Saginaw, MI
In my experience working with Fire Pros service staff I lost prefer Alex. He is articulate, thoughtful, thorough, accurate and efficient. He is also easy to talk with and friendly.
Great service
Matt - Saginaw, MI
The guys that came out were very friendly, helpful and knowledgeable. We would be glad to have them back for future needs
Great service
Matt - Saginaw, MI
Great Service
Hope - Saginaw, MI
friendly and informative
Chris - Saginaw, MI
good to go
Awesome service
Starreese - Saginaw, MI
Sean was pleasant and did an awesome job
Response from Fire Pros, LLC:
Thank you for leaving a review, we greatly appreciate your feedback! Sean is an awesome asset and we want to create value for you and your organization! In the meantime, please consider reviewing us on Google as well. https://tinyurl.com/yylegs7q Thanks again and have a fire safe day
friendly and informative
Chris - Saginaw, MI
wish they could test roll up door.
Response from Fire Pros, LLC:
Thank you for leaving your review! We greatly appreciate your feedback and are glad that we provided you valuable service! At your convenience, please consider sharing your experience on Google as well. https://tinyurl.com/yylegs7q Thanks again and have a fire safe day!
Great service from Tech Alex add multiple problems programming and he has been the only one that had corrected what previous tech's have not.
Lori - Saginaw, MI
Feel that service fee should be wave for this service as this has been a continuation from previous visit.
Great service
Nick - Saginaw, MI
Good teamwork by Fire pros technicians
friendly and informative
Chris - Saginaw, MI
Great Service
Ginger - Saginaw, MI
The tech was very polite and cared about not being a disturbance to others. Very professional.
Response from Fire Pros, LLC:
Thank you for leaving a review, we greatly appreciate your feedback! Alex is an awesome asset and we want to create value for you and your organization! In the meantime, please consider reviewing us on Google as well. https://tinyurl.com/yylegs7q Thanks again and have a fire safe day!
Very Friendly, helped us out quickly!
Denise Beck, Operations Manager, Shields Comfort - Saginaw, MI
Up front about the service he provided and the follow up. Very courteous.
Response from Fire Pros, LLC:
Thank you for leaving a review, we greatly appreciate your feedback! Sean is an awesome asset and we want to create value for you and your organization, Thanks again and have a fire safe day! Also if you have time, please visit Google and leave us a review there as well, we would greatly appreciate it!
timely response and quality service
Nick - Saginaw, MI
Very thoroughly completed required tasks.
Alex R.
Replaced Smoke Detector in Hallway by Room 10 and Tested ***All Systems Normal and Reset ***
Alex R.
CORRECTED DEFICIENCY FROM RECENT INSPECTION EXISTING SMOKE DETECTOR FUNCTIONS AS DESIGNED, AFTER FURTHER TROUBLE SHOOTING FOUND THAT ZONE 13 WAS PROGRAMED AS A INCORRECT ZONE TYPE WHICH WAS NOT ALLOWING SMOKE DETECTOR TO REPORT AND TRIP PROPERLY. REPROGRAMMED SMOKE DETECTOR AND TESTED ZONE TO CENTRAL STATION AND RESET SYSTEM. VERIFIED SIGNALS WITH CENTRAL STATION, AND PUT SYSTEM BACK ON-LINE.***ALL SYSTEMS NORMAL AND RESET ***
Alex R.
CORRECTED DEFICIENCY FROM RECENT INSPECTION EXISTING SMOKE DETECTOR FUNCTIONS AS DESIGNED, AFTER FURTHER TROUBLE SHOOTING FOUND THAT ZONE 13 WAS PROGRAMED AS A INCORRECT ZONE TYPE WHICH WAS NOT ALLOWING SMOKE DETECTOR TO REPORT AND TRIP PROPERLY. REPROGRAMMED SMOKE DETECTOR AND TESTED ZONE TO CENTRAL STATION AND RESET SYSTEM. VERIFIED SIGNALS WITH CENTRAL STATION, AND PUT SYSTEM BACK ON-LINE.***ALL SYSTEMS NORMAL AND RESET ***
Alex R.
CORRECTED DEFICIENCY FROM RECENT INSPECTION EXISTING SMOKE DETECTOR FUNCTIONS AS DESIGNED, AFTER FURTHER TROUBLE SHOOTING FOUND THAT ZONE 13 WAS PROGRAMED AS A INCORRECT ZONE TYPE WHICH WAS NOT ALLOWING SMOKE DETECTOR TO REPORT AND TRIP PROPERLY. REPROGRAMMED SMOKE DETECTOR AND TESTED ZONE TO CENTRAL STATION AND RESET SYSTEM. VERIFIED SIGNALS WITH CENTRAL STATION, AND PUT SYSTEM BACK ON-LINE.***ALL SYSTEMS NORMAL AND RESET ***
Sean W.
Alex R.
Corrected Deficiencies from recent inspection Replaced 4-194 Degree Fixed Heat Detectors and Updated 2020 Inspection Report ***All Systems Normal and Reset ***
Alex R.
Completed Annual Fire Alarm inspection for 2020
Alex R.
Completed Annual Fire Alarm and Nurse Call inspections for 2020
Alex R.
Completed Annual Fire Alarm and Bi-Annual Smoke Detector Sensitivity Inspections for 2020
Alex R.
CHECKED SYSTEM LOOP (POSSIBLE LOOSE WIRING CONNECTION) ALSO LOAD TESTED AND REPLACED FACP BATTERIES ***All Systems Normal and Reset *** Work Approved by Matt Maynard Also Dropped off Nurse Call Pull Cord Requested by Matt Maynard For (2485 AL)
Russ F.
Sprinkler Emergency Service Call
Alex R.
Arrived On-Site Nurse Call system was powered down. Re-Applied power, and Reset Call lights that were tripped on panel. Also explained nurse call system to staff member. System is Reset and Normal.
Alex R.
Arrived On-Site Front Door Power Supply was without Power. Checked breaker Panels Located breaker in Mechanical Room (Panel B Circuit 2 Labeled Outlets in Living Room) was Switched off. Turned breaker back on. Power Supply has power and front door Vonduprin bar is functioning. Tested bar and reset. ***All Systems Normal and Reset ***
Alex R.
Corrected Deficiencies from recent inspection Replaced 12-135 Fixed Heat Detectors and Tested ***All Systems Normal and Reset ***
Christian L.
Mike R.
Deficiency: THE FOLLOWING BATTERIES FAILED LOAD TEST AND REQUIRE REPLACEMENT FACP 2-12 volt 18 ah F2 NAC PNL 2-12 volt 12 ah
Mike R.
Fire Alarm Inspection (6) mp, (11) sd, (5) DD with test rest switches, (18) hd, (4) beam detectors. Need 12 foot ladder.
Alex R.
Completed Bi-Annual Smoke Detector Sensitivity for 2020
Mark S.
Alex R.
Arrived On-Site FACP Stated All Systems Normal and Reset. Viewed History. It stated NAC 2 was tripping and resetting in and out of trouble. Trouble shot Circuit, found H/S in Hallway by Room 118 was loose from base (loose enough that it pulled right off base like someone purposely disconnected it). Re-Secured H/S and checked rest of 1st Floor. All were secure. Metered circuit. Circuit is now well within normal parameters. Re-Connected circuit and Reset FACP. ***All Systems Normal and Reset*** (Will Monitor System over night to see if trouble re-Triggers.)