Sterling Heights
Local Reviews
for Sterling Heights, MI
James
Ammar - Sterling Heights, MI 48314
James is professional in his job, organized, and pay attention to the smallest details, which make me feel comfortable having him doing annual inspection
Sprinkler Inspection Feedback
Jim - Sterling Heights, MI 48314
It was a pleasure to have Terrence conduct our inspection today, he was both personable and professional. I received our summary report shortly after the inspection was completed which is appreciated!
Great Service
Larry - Sterling Heights, MI 48312
Alway's a pleasure to have FIRE SYSTEMS on site. A++ Professional and Informative Great staff
Fire Pros
SH Bee's - Sterling Heights, MI 48312
Very professional
Great service.
David - Sterling Heights, MI 48312
Great company for your service needs.
Great customer service
Christi - Sterling Heights, MI 48312
So friendly, knowledgeable and speedy!
Great Service
Bryan - Sterling Heights, MI 48310
Great Service!
Ken - Sterling Heights, MI 48312
George was great! walked me through what was going to be serviced and inspected, explained how the system works and showed me how to pull the ansul pull station. Walked me through the inspection before signing off. Very personable, interacted with the Team while he was here.
Professional and Conscientious
Gail - Sterling Heights, MI 48314
Alex was thorough, professional and knows his stuff. Alex explains everything completed and what the results were. I highly recommend him.
great service
David - Sterling Heights, MI 48312
Great service
Rich - Sterling Heights, MI 48312
Excellent service.
Sui - Sterling Heights, MI 48310
Thorough Inspection.
Heather - Sterling Heights, MI 48313
Alex was very thorough in his inspection of our building’s kitchen suppression system. He provided very clear explanations of the things that needed to be addressed, and made sure to check on things he wasn’t 100% certain about.
Manager
Anthony - Sterling Heights, MI 48312
Great job! Very nice and professional
Great Service
Brian - Sterling Heights, MI 48314
great service
Laura - Sterling Heights, MI 48310
Excellent Service
Foezur - Sterling Heights, MI 48314
Great Service
Brian - Sterling Heights, MI 48314
Response from Fire Pros | Fire Systems of MI | Adam's Fire :
Thank you Brian for the 5 star review.
construction manager
Larry - Sterling Heights, MI 48312
cost is what it is...
Response from Fire Pros | Fire Systems of MI | Adam's Fire :
Larry, we appreciate your 5 star review.
Great Service
Brian - Sterling Heights, MI 48314
George S.
James J.
Mark S.
James J.
James J.
Terrence J.
**COMMERCIAL FIRE PAPERWORK ATTACHED** Sprinkler Inspection Annual Sprinkler Inspection ***COMMERCIAL FIRE PAPERWORK REQUIRED*** Deficiency: QR sprinkler heads are outdated. Will need to pull and replace (4) 1/2” QR chrome pendants to send out for UL testing. Deficiency: Sprinkler system is due for five year internal obstruction investigation of piping. 2- 2.5” victaulic couplings Deficiency: Sprinkler system is due for gauge change. 1- sprinkler gauge Deficiency: Sprinkler system is due for five-year Hydro test department connection. Deficiency: Sprinkler system. Quick response. Heads are due for UL testing. 4- 155° chrome pendant sprinkler heads quick response half inch orifice Deficiency: Sprinkler system is due for five year internal investigation, fire department, connection, check valve. 2- 2.5” victaulic couplings Deficiency: 6 inch OS and Y control valve should have chain and lock on it
Mark S.
Mark S.
John R.
Terrence J.
Sprinkler Service Call JB called in a service call to replace a head in the bowling alley.
Mark S.
Mark S.
John S.
Terrence J.
Sprinkler Service Call JB called in a service call to replace a head in the bowling alley.
James J.
Terrence J.
12/11/23 Customer would like to wait until after Holidays Sent email regarding inspection. DH Sprinkler Inspection Annual Fire Sprinkler Inspection of (1) wet type system
Mark S.
Mark S.
Terrence J.
11/15/23 Sent email regarding inspection DH 10/12/23MV Emailed Fredi regarding inspection date 10/20, waiting on confirmation Sprinkler Inspection Annual Fire Sprinkler Inspection (1 Wet, 1 Dry System) Full Flood Due: 2021 Deficiency: Dry pendants in cooler and freezer are more than 10 years old and need to be pulled and sent in for UL testing 155 QR wt pendant 17” Deficiency: 1- 2”x 1/2” galvanize nipple 1 - 1/2” galvanized, 90° elbow 1- 1/2” brass ball drip Fire department connection, check valve missing ball drip Deficiency: System is due for gauge change 3- air water gauges Deficiency: Dry pendants in cooler and freezer are more than 10 years old and need to be pulled and sent in for UL testing 155 QR wt pendant 17” 286° quick response, white pendant 19 inches
Terrence J.
11/9/23 Terrence James has the key. DH Antifreeze Loop Inspection Annual Antifreeze Loop Inspection (1)